Skip to content
Factory-direct from Lahore · Nationwide delivery in 2–4 days +92 319 4262451 WhatsApp
Black and red single-core DC cable coils with an inset of the stripped copper strands inside
PILONE · 25MM² · 1 CORE · CU CLASS 5 · 1000 V DC

25mm DC Solar Cable

Single-core class 5 copper conductor for DC feeder runs on commercial solar installations with larger arrays. PVC insulated, rated to 1000 V DC. Made on the Pilone line in Lahore.

Factory-direct price
Contact for quote
Message us for today’s rate
In stock
WhatsApp for today's rate

Prices track the daily copper rate. Coil and bulk pricing on request.

Specifications

Resistance per IEC 60228. Current capacity uses BS 7671 method C (clipped direct), 30°C ambient, as the nearest published reference for a two-conductor DC run, the positive and return pair — actual solar-circuit ampacity depends on run length, grouping, and your inverter or charge-controller rating. Verify sizing with a licensed electrician or your solar installer.
PropertyValue
ConductorPlain annealed copper, class 5 flexible stranded
Nominal area25 mm² × 1 core
Strand construction196 / 0.40 mm
Max conductor resistance at 20°C0.78 Ω/km
Current capacity (two loaded conductors — DC positive and return)112 A
Voltage drop1.75 mV/A/m
Voltage rating1000 V DC
Insulation / sheathPVC / PVC, 70°C conductor rating
Conductor copper weight≈ 222.3 kg/km
Reference standardsIEC 60228 (conductors), IEC 60227 (PVC cables)
This is the standard PVC-insulated construction, 70°C conductor rating. An XLPE/PVC construction rated to 90°C is also available for exposed outdoor runs — ask when you message us.

Voltage drop on a 25 mm² solar run

On a DC circuit the current goes out on the positive and back on the negative. At this cable's 1.75 mV/A/m, the volts lost over a one-way run are:

Volts lost on 25 mm² DC cable, positive and return, at 1.75 mV/A/m.
Current10 m run20 m run30 m run
50 A0.88 V1.75 V2.63 V
63 A1.10 V2.21 V3.31 V
80 A1.40 V2.80 V4.20 V
100 A1.75 V3.50 V5.25 V

The same loss matters more at low voltage: 1.75 V over a 10 m run at 100 A is 3.6% of a 48 V battery bank but 0.44% of a 400 V panel string. Check the loss limit your inverter maker gives, or work it through the voltage drop calculator.

Next size up or down

DC solar cable sizes either side of 25 mm², same reference conditions as the specification table.
SizeCurrent capacityVoltage dropCopper per 100 m
16 mm²85 A2.8 mV/A/m14.2 kg
25 mm² (this cable)112 A1.75 mV/A/m22.2 kg
35 mm²138 A1.25 mV/A/m31.1 kg

Other DC cable sizes

Two-conductor DC reference current, BS 7671 method C, 30°C ambient. Same class 5 copper construction in every size.

Frequently asked

What is the price of 25mm DC cable in Pakistan?
The price moves with the daily copper rate, so we quote it the day you order. We sell factory-direct from Lahore, with no dealer margin on top. Message us on WhatsApp for today's price per meter.
What is 25mm DC cable used for?
DC feeder runs on commercial solar installations with larger arrays. It is rated 112 A on the BS 7671 method C reference and 1000 V DC.
Can I get 25mm DC cable delivered?
Yes. We dispatch from Lahore — courier for single coils, transport for bulk. Punjab arrives in 1–2 days, the rest of Pakistan in 2–4 days. See delivery details.

Send us the length and your city

We quote 25mm DC cable at the day's copper rate and dispatch from the Lahore line. Tell us the construction and how many meters you need.

WhatsApp for today's rate