PILONE · 4MM² · 4 CORE · 450/750 V · CU CLASS 2

4mm 4 Core Standard Cable

4.8/5 · 127 buyer ratings

PILONE CABLES TECHNICAL TEAM

Four 4 mm² class 2 conductors under one PVC sheath — three phases and a neutral — 7 strands of 0.85 mm per core, the size the counter still orders as 7/.036. 32 A with three loaded conductors, 4.61 Ω/km, 450/750 V. This is the smallest four core we build in the standard class 2 range: one cable and one gland to feed a workshop board or a small three-phase motor, about 22 kVA at 400 V. Made on the Pilone line in Lahore.

Factory-direct price
Contact for quote
In stock
Message us for today’s rate
WhatsApp for today's rate

Prices track the daily copper rate. Bulk and coil pricing on request.

Check the coil before you pay for it

Every coil leaves our factory with a QR code printed on the packaging. Scan it and the factory record for that batch opens: brand, cable size, batch number, year of manufacture and conductor. Compare the batch number on screen with the one printed on your coil — if the two do not match, it did not come from us.

4mm 4 core cable is quoted at the day's copper rate, per metre.

4 mm² 4 core standard cable is quoted at the day's copper rate, per metre — send the metres and your city on WhatsApp and today's number comes back. Three of the four conductors are loaded on a three-phase circuit, so the cable carries 32 A on BS 7671 reference method C at 30°C, about 22.2 kVA at 400 V. In the trade this size is still ordered as 7/.036, which computes to 4.6 mm² and is sold as 4.

Per metre, per foot or per coil?

Quotes for 4mm cable come back per metre, per foot and per coil, and the unit is often left out. Per foot always sounds cheapest because a foot is under a third of a metre. A coil price says nothing until you know the coil's length. Reduce every quote to a rate per metre before you compare, and say the core count — at 4 mm² the two, three and four core builds all sit on the same shelf.

Unit conversions only, no prices. 1 ft = 0.3048 m and 1 yard = 0.9144 m, so 1 m = 3.281 ft = 1.094 yards. Coil lengths are not standardised in Pakistan — confirm the metre count of the coil you are actually buying.
Quoted asLength in metresTo get the per-metre rate
Per metre1 mNothing to do
Per foot0.305 mMultiply the per-foot rate by 3.281
Per yard0.914 mMultiply the per-yard rate by 1.094
Per 90 m coil90 m (295 ft)Divide the coil price by 90
Per 45 m half coil45 m (148 ft)Divide by 45
Per 100 m drum100 m (328 ft)Divide by 100

Coil lengths are not standardised in Pakistan, so get the metre count written on the invoice before you pay rather than after. We quote per metre against the length you give us. The price per meter page covers every conversion, and how cable is priced in Pakistan explains why the rate moves with copper.

How much current 4mm 4 core cable carries

32 A with three conductors loaded, 36 A with two, clipped direct at 30°C. That 32 A is about 22.2 kVA on a 400 V supply (1.732 × 400 × 32 ÷ 1000) — the size that typically feeds a small three-phase motor, a shop unit or a submain to an outbuilding.

Class 2 fixed-wiring copper, four-core, three loaded. Current capacity and voltage drop per BS 7671, installation reference method C (clipped direct), 30°C ambient; conductor resistance and stranding per IEC 60228. Two loaded conductors is a single-phase circuit with its earth; three loaded is three phases. Copper mass computed at 8.89 kg/km per mm² per core, conductor only. Verify sizing with a licensed electrician for your installation.
SizeStrands2 loaded3 loadedVoltage dropCopper in a 90 m coil
1.5 mm²7/0.5319.5 A17.5 A29 mV/A/m4.8 kg
2.5 mm²7/0.6727 A24 A18 mV/A/m8.0 kg
4 mm²7/0.8536 A32 A11 mV/A/m13 kg
6 mm²7/1.0446 A41 A7.3 mV/A/m19 kg
10 mm²7/1.3563 A57 A4.4 mV/A/m32 kg
16 mm²7/1.7085 A76 A2.8 mV/A/m51 kg

Voltage drop at 11 mV/A/m is what usually limits this size rather than heat. At the full 32 A the 20 V that BS 7671's 5% allows on a 400 V circuit is spent at 57 m; on a single-phase run at 36 A the 11 V budget is gone at 28 m. Those distances are short enough that a submain to the far end of a plot often wants 6 mm² even though the load would sit inside 4.

All of these are clipped-direct figures at 30°C. Pull the cable through conduit, bundle it with other circuits, or run it under a Lahore roof in June and it carries less — BS 7671 handles that with correction factors rather than one invented figure. Work yours out with the cable size calculator and the voltage drop calculator, then have a licensed electrician confirm it.

Specifications

Resistance per IEC 60228. Current capacity and voltage drop per BS 7671, installation method C (clipped direct), 30°C ambient, 3 loaded conductors. Verify sizing with a licensed electrician for your installation.
PropertyValue
ConductorPlain annealed copper, class 2 stranded
Nominal area4 mm² × 4 cores
Strand construction7 / 0.85 mm per core (typical)
Max conductor resistance at 20°C4.61 Ω/km
Current capacity (method C, 3 loaded)32 A
Voltage drop11 mV/A/m
Voltage rating450/750 V
Insulation / sheathPVC / PVC, 70°C conductor rating
Conductor copper weight≈ 142 kg/km (4 × 35.6 kg/km)
Reference standardsIEC 60228 (conductors), IEC 60227 (PVC cables)

Strand codes: what 7/.036 comes to

Much of the Pakistani trade still orders by strand code, and the code says two things: how many strands, and how thick each one is in inches. 7/.036 is seven strands of 0.036 inch wire. The arithmetic checks any code: 0.036 × 25.4 = 0.914 mm across, area = 0.7854 × 0.914² = 0.66 mm² per strand, × 7 = 4.6 mm².

Computed area = 0.7854 × (strand diameter in inches × 25.4)² × strand count. Nominal metric sizes per IEC 60228. The imperial codes do not land exactly on the metric names — some sit above, some below. Both numbers are published here so you can check either way.
CodeStrand diameterComputed areaSold as
3/.0290.737 mm1.29 mm²1.5 mm²
7/.0290.737 mm3.0 mm²2.5 mm²
7/.0360.914 mm4.6 mm²4 mm²
7/.0441.118 mm6.9 mm²6 mm²
7/.0521.321 mm9.6 mm²10 mm²
7/.0641.626 mm14.5 mm²16 mm²
19/.0521.321 mm26 mm²25 mm²

So 7/.036 computes to 4.6 mm² and is sold as 4 mm² — the imperial code sits slightly above the metric name it is sold under, and the specification table above gives the metric 7/0.85 build this cable is actually made to. Ask for 4mm cable or for 7/.036 and you are asking for the same conductor; add the core count or you will be handed whichever build is nearest. The wire strand codes guide carries the full vocabulary, and 4mm vs 6mm cable covers the step up.

Where this cable belongs

The buyer for this one almost always has a three-phase connection on a small premises: a workshop with a lathe and a compressor, a shop taking its own sub-board off the main panel, a tubewell starter a short walk from the meter. Four cores means three phases plus the neutral in one sheath, so a 400 V board is fed with one cable and one gland instead of four singles in conduit. 32 A with three loaded conductors, clipped direct at 30°C — about 22 kVA on a 400 V supply (1.732 × 400 × 32 ÷ 1000). Wire the same cable single-phase and only two conductors are loaded, which lifts it to 36 A. The imperial code for this size is 7/.036, computing to 4.6 mm² of copper; both numbers are worked out on the 7/.036 single core page.

Small three-phase submains

Main panel to a shop, annexe or workshop board where the diversified total stays under 32 A — roughly 22 kVA at 400 V.

Small motor feeders

Fixed runs to three-phase pumps and compressors. Size on the full-load amps printed on the motor plate, not on the horsepower on the box.

Machine drops in a shed

Clipped or in trunking to a fixed machine. If the tail has to move or coil, the class 5 build is the one to use, not this.

Worked example, from the table above. A 4 kW three-phase motor at 400 V and 0.85 power factor draws 4000 ÷ (1.732 × 400 × 0.85) = 6.8 A — read the plate on your own motor, because that figure is the one to size on. Over a 40 m run the drop is 6.8 × 40 × 11 ÷ 1000 = 3.0 V, against the 20 V that BS 7671's 5% allows on a 400 V power circuit. Push the same cable to its rated 32 A and that 20 V arrives at 20000 ÷ (32 × 11) = 57 m. Under that length the load picks the size; past it the run does, and the next step is 6mm 4 core cable at 41 A and 7.3 mV/A/m.

Current capacity depends on how the cable is installed. Derate for conduit, grouping, and high ambient temperature. Have a licensed electrician confirm the size for your load and run length — or start with the cable size calculator.

Also made in 2 and 3 core

Core count follows the circuit, not the load. Two core is line and neutral with the earth taken separately. Three core is line, neutral and earth, or three phases without a neutral. Four core is three phases plus a neutral. The conductor is the same 4 mm² copper throughout; only the number of loaded conductors changes.

4 mm² copper, class 2, 450/750 V. Current capacity per BS 7671 reference method C (clipped direct), 30°C ambient, by number of loaded conductors. Verify sizing with a licensed electrician for your installation.
CoresWhat runs in itLoadedCurrent capacity
2 coreLine and neutral, earth run separately236 A
3 coreLine, neutral and earth — or three phases, no neutral2 or 336 A / 32 A
4 coreThree phases plus neutral332 A

The same size in the other builds: 4mm 2 core standard cable and 4mm 3 core standard cable. One step up in the same four-core build is 6mm 4 core standard cable at 41 A, then 10mm 4 core cable at 57 A. Where the run has to flex, the class 5 equivalent is 4mm 4 core flexible cable.

Check the coil before you pay

“Full gauge” is a claim that rarely arrives with a test attached. Here are three you can run yourself on any seller's cable, ours included.

Weigh the copper

Conductor mass = area × cores × 8.89 kg/km per mm². For 4 mm² 4 core that is 4 × 4 × 8.89 = 142 kg/km, so a 90 m coil holds about 12.8 kg of copper before insulation and sheath.

Measure the strands

Cut the end square. A 4 mm² class 2 core is 7 strands of about 0.85 mm. Seven strands of a visibly thinner wire is a smaller conductor whatever the sheath is printed with.

Measure the length

Get the metre count in writing before you pay, then check it with a measuring wheel. A short coil is the quietest way a per-coil price stops being the price you calculated.

What buyers say

5/5

“Excellent quality copper cables. Fast delivery across Pakistan. Highly recommended for electrical projects.”

AHMAD HASSAN

5/5

“Best cable manufacturer in Lahore. 99.9% pure copper as promised. Very satisfied with the product quality.”

MUHAMMAD ALI

5/5

“Good quality cables at competitive prices. Delivery was quick to Karachi. Will order again.”

IMRAN KHAN

Frequently asked

What is the price of 4mm 4 core cable in Pakistan?
The price changes with the daily copper rate. Pilone Cables sells factory-direct from Lahore, below dealer rates. Message us on WhatsApp at +92 319 4262451 for today's price per meter.
What is 4mm 4 core cable used for?
It carries 3-phase power for smaller loads: submains from a main panel to a sub-distribution board, and feeders for small pumps or compressors. Rated around 32 A installed clipped direct.
Do I need flexible cable instead?
Use flexible cable only where the run bends or feeds equipment that moves. For a fixed submain, standard cable is the normal choice.
How many amps does 4mm 4 core cable carry?
32 A with three loaded conductors — three phases — clipped direct at 30°C on BS 7671 reference method C. That is about 22 kVA on a 400 V three-phase supply. Wire the same four cores as a single-phase circuit and only two are loaded, which lifts the figure to 36 A. In conduit, bunched with other circuits, or in summer heat, the correction factor comes off first.
Is 4mm 4 core cable enough for a three-phase submain?
For a small one, yes. 32 A across three phases is roughly 22 kVA at 400 V, which covers a workshop board with a few machines or a shop annexe. Add the connected loads, apply diversity, then compare the total against 32 A. Past about 57 m at full load, voltage drop rather than heat picks the size, and the step up is 6mm 4 core cable at 41 A.