4mm 2 core standard cable with the black sheath cut back, showing the red and black insulated cores and their stranded copper conductors
PILONE · 4MM² · 2 CORE · 450/750 V · CU CLASS 2

4mm 2 Core Standard Cable

PILONE CABLES TECHNICAL TEAM

4.8/5 · 127 buyer ratings

36 A, 7/0.85 class 2 copper, 450/750 V. The size that goes to an AC point or a socket submain, PVC insulated and sheathed, drawn on the Pilone line in Lahore.

Factory-direct price
Contact for quote
In stock
Message us for today’s rate
WhatsApp for today's rate

Quoted per metre at the day's copper rate. Send the length in metres and your city for the coil figure.

Check the coil before you pay for it

Every coil leaves our factory with a QR code printed on the packaging. Scan it and the factory record for that batch opens: brand, cable size, batch number, year of manufacture and conductor. Compare the batch number on screen with the one printed on your coil — if the two do not match, it did not come from us.

36 A — the size for a 1.5 ton AC point or a socket submain.

4mm² 2 core standard cable carries 36 A with both conductors loaded, clipped direct at 30°C, which leaves real margin over the 7–9 A a 1.5 ton air conditioner draws and over the 20 A MCB that protects it. Line and neutral only, so the earth arrives separately. The rate is quoted per metre at the day's copper price, and the coil figure follows from the length you need.

Specifications

4mm² 2 core standard cable is rated 36 A with two loaded conductors on BS 7671 reference method C (clipped direct) at 30°C ambient. Its conductors are class 2 stranded copper, seven strands of 0.85 mm each, resistance capped at 4.61 Ω/km by IEC 60228, voltage drop 11 mV per amp per metre. In the bazaar the same size is called 7/.036, an imperial strand code that computes to 4.60 mm². Derate the 36 A for conduit, grouping and ambient above 30°C, and have a licensed electrician confirm the size for the run.

Resistance per IEC 60228. Current capacity and voltage drop per BS 7671, installation reference method C (clipped direct), 30°C ambient, two loaded conductors. Copper weight is the two conductors only, before insulation and sheath. Verify sizing with a licensed electrician for your installation.
PropertyValue
ConductorPlain annealed copper, class 2 stranded
Nominal area4 mm² × 2 cores
Strand construction7 / 0.85 mm per core
Market strand code7/.036 (computes to 4.60 mm²)
Max conductor resistance at 20°C4.61 Ω/km
Current capacity (method C, 2 loaded)36 A
Voltage drop11 mV/A/m
Voltage rating450/750 V
Insulation / sheathPVC / PVC, 70°C conductor rating
Conductor copper weight71.2 kg/km (2 × 35.6 kg/km)
Copper in a 90 m coil6.4 kg
Reference standardsIEC 60228 (conductors), IEC 60227 (PVC cables)

Worked at a real run: a 1.5 ton AC drawing 8 A over 25 m of 4mm² drops 8 × 25 × 11 ÷ 1000 = 2.2 V, against the 11 V that BS 7671's 5% allowance gives on a 220 V supply. Even a 30 A socket submain over 30 m only drops 30 × 30 × 11 ÷ 1000 = 9.9 V — inside the limit, but close enough that the next size up is worth pricing. Check yours in the voltage drop calculator.

Per metre, per foot, or per coil

A price without a unit tells you nothing, and this market prints plenty of them. Per foot and per metre differ by a factor of 3.281. Coil is not a fixed quantity either: 30 m, 45 m and 90 m packs are all sold, some sellers quote 301 ft, and 80-yard lengths exist. Get the length in metres in writing, then divide.

Conversions, not prices. Copper weight is the two conductors at 71.2 kg per km of cable, before PVC. Divide any coil quote by the length in metres for the rate per metre; divide that by 3.281 for the rate per foot.
PackLengthIn feetCopper inside
Cut length1 m3.281 ft0.07 kg
Half coil45 m148 ft3.2 kg
Full coil90 m295 ft6.4 kg
301 ft coil91.7 m301 ft6.5 kg

The copper column is a check anyone can run. Copper weighs 8.89 kg per km for every mm², so 4 mm² across two cores is 8 × 8.89 = 71.2 kg per km, and a 90 m coil holds 6.4 kg of bare conductor. PVC and the drum add weight on top, so a real coil weighs more; it should never weigh less. More unit arithmetic on the price per metre page.

Where this cable belongs

AC and geyser points

A dedicated run to a 1.5 ton AC on a 20 A MCB, or to a storage geyser on a 25 A MCB.

Socket circuit submains

Main panel to a sub-board serving kitchen or bedroom sockets in a 3 or 5 marla house.

Lighting submains

Long lighting runs where 2.5mm² would pass on current but fail on voltage drop.

36 A is the clipped-direct figure at 30°C. In conduit, bunched with other circuits, or in a Lahore summer, the cable carries less — BS 7671 applies an ambient correction factor and a grouping factor, and the usable current is the tabulated 36 A multiplied by both. Have a licensed electrician apply the factors for your installation and confirm the size for your load and run length, or start with the cable size calculator.

Loads that land on 4mm²

Most buyers reach this size from a job, not a number. Three of the common ones, with the current each draws on a 220 V single-phase supply. Always confirm against the rating plate on your own unit.

4mm² in 2, 3 and 4 core, and the sizes either side

Current capacity per BS 7671 reference method C (clipped direct), 30°C ambient, class 2 copper except where the flexible build is named. Two loaded conductors on the 2 and 3 core builds, three on the 4 core. Verify sizing with a licensed electrician for your installation.
CableCurrentWhere it goes
4mm 2 core standard cable (this page)36 ALine and neutral, earth taken separately
4mm 3 core standard cable36 ASame run with its own earth core
4mm 4 core standard cable32 ALight three-phase runs at 400 V
6mm 2 core standard cable46 AOne size up: long runs and heavier submains
4mm 2 core flexible cable36 AClass 5, for cable that moves or bends
4mm (7/.036) single core wire36 AOne conductor per sheath, pulled through conduit

What buyers say

5/5

“Excellent quality copper cables. Fast delivery across Pakistan. Highly recommended for electrical projects.”

AHMAD HASSAN

5/5

“Best cable manufacturer in Lahore. 99.9% pure copper as promised. Very satisfied with the product quality.”

MUHAMMAD ALI

5/5

“Good quality cables at competitive prices. Delivery was quick to Karachi. Will order again.”

IMRAN KHAN

Frequently asked

What is the price of 4mm 2 core cable in Pakistan?
It moves with the daily copper price, so the figure is quoted on the day you order. Ask for it per metre — a per-foot number looks 3.281 times cheaper for the same cable, and a coil price means nothing until the coil length is stated. Factory-direct from the Lahore line, no dealer margin.
What is 4mm 2 core cable used for?
Fixed single-phase wiring inside a building: a dedicated AC point, a socket circuit submain, a lighting submain to a sub-board, and appliance circuits such as water heaters. It carries 36 A with two conductors loaded, clipped direct at 30°C, on a breaker rated below that.
Is 4mm cable enough for a 1.5 ton AC?
Yes, and it is the size to use. A 1.5 ton split or window unit typically draws 1500–1800 W, about 7 to 9 A at 220 V, with a compressor start two to three times that for a moment. 4mm² is rated 36 A clipped direct, so the circuit keeps margin after derating for conduit and summer heat.
Is 4mm cable the same as 7/.036?
They are sold as the same size. 7/.036 is the imperial strand code — seven strands of 0.036 in, which is 0.914 mm, computing to 4.60 mm². Our standard series is built to the metric size, seven strands of 0.85 mm. Both have to meet the IEC 60228 resistance cap of 4.61 Ω/km.
Should I use 2 core or 3 core 4mm cable?
Two core carries line and neutral only, so the earth has to arrive another way, usually a separate earth conductor or the conduit system. Three core brings its own earth in the same sheath, which is the cleaner job on an appliance point. Both 4mm builds carry 36 A.