Three 10mm² class 5 cores in one sheath — three phases to a machine that gets moved, or live, neutral and earth to heavy single-phase gear dropped down a borewell and dragged across a yard. 80 strands of 0.40 mm per core is what lets it bend all day without work-hardening. 57 A on method C with all three cores loaded as phases; give the third core to earth and only two are loaded, so the same cable is good for 63 A. 1.91 Ω/km, 4.4 mV/A/m, 300/500 V. Drawn on the Pilone line in Lahore.

Factory-direct price
Contact for quote
In stock
Message us for today’s rate
WhatsApp for today's rate

Prices track the daily copper rate. Bulk and coil pricing on request.

Check the coil before you pay for it

Every coil leaves our factory with a QR code printed on the packaging. Scan it and the factory record for that batch opens: brand, cable size, batch number, year of manufacture and conductor. Compare the batch number on screen with the one printed on your coil — if the two do not match, it did not come from us.

10mm 3 core flexible cable is quoted at the day's copper rate, per metre.

10 mm² 3 core flexible cable is quoted at the day's copper rate, per metre — send the metres and your city on WhatsApp and today's number comes back. Which rating applies depends on the circuit: line, neutral and earth loads two conductors and the cable carries 63 A on BS 7671 reference method C at 30°C, about 13.9 kVA at 220 V; three phases with no neutral loads all three and the figure is 57 A, about 39.5 kVA at 400 V. The class 5 conductor is 80 strands of 0.40 mm, which is what lets the cable be coiled between jobs.

Per metre, per foot or per coil?

Most people arriving at a 10mm 3 core cable price in Pakistan are comparing quotes that are not comparable. A bare figure with no unit, a per-foot rate that flatters itself because a foot is under a third of a metre, a coil price with no metre count attached. Reduce all of them to a rate per metre before you decide, and state “flexible” rather than just the size, because the standard build is a different cable.

Unit conversions only, no prices. 1 ft = 0.3048 m and 1 yard = 0.9144 m, so 1 m = 3.281 ft = 1.094 yards. Coil lengths are not standardised in Pakistan — confirm the metre count of the coil you are actually buying.
Quoted asLength in metresTo get the per-metre rate
Per metre1 mNothing to do
Per foot0.305 mMultiply the per-foot rate by 3.281
Per yard0.914 mMultiply the per-yard rate by 1.094
Per 90 m coil90 m (295 ft)Divide the coil price by 90
Per 45 m half coil45 m (148 ft)Divide by 45
Per 100 m drum100 m (328 ft)Divide by 100

Coil lengths are not standardised in Pakistan, so a coil is a container rather than a quantity. Get the metre count onto the invoice before you pay. We quote per metre against the length you give us. The price per meter page covers every conversion, and how cable is priced in Pakistan explains what moves the number.

How much current 10mm 3 core flexible cable carries

63 A with two conductors loaded, 57 A with three. The size ladder below is the useful context: each step up buys current, and buys back run length as the voltage drop per amp-metre falls.

Class 5 flexible copper, three-core. Current capacity and voltage drop per BS 7671, installation reference method C (clipped direct), 30°C ambient; conductor resistance and stranding per IEC 60228. Two loaded conductors is a single-phase circuit with its earth; three loaded is three phases with no neutral. Copper mass computed at 8.89 kg/km per mm² per core, conductor only. Verify sizing with a licensed electrician for your installation.
SizeStrands (class 5)2 loaded3 loadedVoltage dropCopper in a 90 m coil
4 mm²56/0.3036 A32 A11 mV/A/m9.6 kg
6 mm²84/0.3046 A41 A7.3 mV/A/m14 kg
10 mm²80/0.4063 A57 A4.4 mV/A/m24 kg
16 mm²126/0.4085 A76 A2.8 mV/A/m38 kg

Voltage drop is where this size is usually decided rather than heat. At 4.4 mV/A/m the 11 V that BS 7671's 5% allows on a 220 V circuit is spent at 11 ÷ (63 × 4.4 ÷ 1000) = 40 m with the cable at its full 63 A. On three loaded conductors at 400 V the budget is 20 V and the distance is 20 ÷ (57 × 4.4 ÷ 1000) = 80 m. Step up to 16 mm² and the same load reaches roughly half as far again, which is often cheaper than moving the board.

These figures assume the cable is clipped direct in open air at 30°C. A flexible cable left wound on its drum under load cannot shed heat and must be run out first. Conduit, bundling and high ambient temperature each take another bite, handled in BS 7671 by correction factors rather than by one invented “real world” number. Work yours out with the cable size calculator and the voltage drop calculator, then have a licensed electrician confirm it.

Specifications

Resistance per IEC 60228. Current capacity and voltage drop per BS 7671, installation method C (clipped direct), 30°C ambient: 57 A with 3 loaded conductors, 63 A with 2 loaded and the third core as earth. Verify sizing with a licensed electrician for your installation.
PropertyValue
ConductorPlain annealed copper, class 5 flexible stranded
Nominal area10 mm² × 3 cores
Strand construction80/0.40 mm per core (typical)
Max conductor resistance at 20°C1.91 Ω/km
Current capacity (method C)57 A (3 loaded) / 63 A (2 loaded + earth)
Voltage drop4.4 mV/A/m
Voltage rating300/500 V
Insulation / sheathPVC / PVC, 70°C conductor rating
Conductor copper weight≈ 267 kg/km (3 × 88.9 kg/km)
Reference standardsIEC 60228 (conductors), IEC 60227 (PVC cables)

Worked example, using the 4.4 mV/A/m in the table. A pump lead carrying 25 A down a 60 m drop loses 25 × 60 × 4.4 ÷ 1000 = 6.6 V, which is 3% of a 220 V supply and inside the 5% BS 7671 allows on a power circuit. Take the same 25 A to 100 m and the drop is 11 V — exactly that 5%. Below that depth the metres have chosen the size for you, and the next step is 16mm 3 core flexible cable at 2.8 mV/A/m. On a borewell it is nearly always the depth, not the motor, that sets the cable.

Class 5 against class 2: why this one bends

Flexible and standard are the same copper and the same 10 mm². The difference is how the area is divided. Class 5 splits it into 80 strands of 0.40 mm; class 2 uses 7 strands of 1.35 mm. Thin strands slide past each other as the cable bends, so the conductor tolerates being coiled and uncoiled; a thick-stranded class 2 core flexed often enough will fatigue and break inside a sheath that still looks perfect.

10 mm² copper conductor, both classes, per IEC 60228. Resistance is the maximum permitted at 20°C. Current capacity is identical because it follows conductor area and installation method, not stranding.
PropertyClass 5 (flexible)Class 2 (standard)
Strands80/0.407/1.35
Max resistance1.91 ohm/km1.83 ohm/km
Current capacity57 A / 63 A57 A / 63 A
Bends repeatedlyYesNo
Typical useTrailing leads, portable toolsFixed wiring, trays, conduit

The class 5 build's slightly higher resistance is permitted by the standard and does not change what the cable carries. Buy flexible when the cable will move. For a run that is clipped up once and forgotten, 10mm 3 core standard cable is the same copper in the cheaper build.

Where this cable belongs

Borewell pump drop leads

Live, neutral and earth down to a single-phase motor. The earth core in the same sheath is the reason 3 core is the standard choice on a pump.

Earthed machine and appliance cords

Welding sets, compressors and mixers on their own lead, where the earth must travel with the supply and the cable is coiled after every shift.

Three-phase machines with no neutral

Three phases on the three cores. All three are loaded, so the figure is 57 A rather than 63 A — about 39 kVA at 400 V.

Current capacity depends on how the cable is installed and how it's coiled or bundled. Derate for high ambient temperature and long trailing runs. Have a licensed electrician confirm the size for your load — or start with the cable size calculator.

Also made in 2 and 4 core

Core count follows the circuit. Two core is line and neutral with a separate earth. Three core is line, neutral and earth — or three phases without a neutral. Four core is three phases plus a neutral. Same 10 mm² conductor throughout; what changes is how many of them are loaded.

10 mm² class 5 flexible copper, 300/500 V. Current capacity per BS 7671 reference method C (clipped direct), 30°C ambient, by number of loaded conductors. Verify sizing with a licensed electrician for your installation.
CoresWhat runs in itLoadedCurrent capacity
2 coreLine and neutral, earth run separately263 A
3 coreLine, neutral and earth — or three phases, no neutral2 or 363 A / 57 A
4 coreThree phases plus neutral357 A

The same size in the other builds: 10mm 2 core flexible cable and 10mm 4 core flexible cable. One step up is 16mm 3 core flexible cable at 76 A on three loaded conductors; one step down, 6mm 3 core flexible cable at 41 A.

Check the coil before you pay

Three checks you can run yourself on any seller's cable, ours included. A weighing scale, a tape and a vernier will settle a “full gauge” claim in about ten minutes.

Weigh the copper

Conductor mass = area × cores × 8.89 kg/km per mm². For 10 mm² 3 core that is 10 × 3 × 8.89 = 267 kg/km, so a 90 m coil holds about 24 kg of copper before insulation and sheath.

Measure the strands

A class 5 core at this size is about 80 strands of 0.40 mm. Cut the end square and count. Far fewer, thicker strands means a class 2 conductor being sold as a flexible one.

Measure the length

Get the metre count in writing before you pay, then check it with a measuring wheel. A short coil is the quietest way a per-coil price stops being the price you calculated.

What buyers say

5/5

“Excellent quality copper cables. Fast delivery across Pakistan. Highly recommended for electrical projects.”

AHMAD HASSAN

5/5

“Best cable manufacturer in Lahore. 99.9% pure copper as promised. Very satisfied with the product quality.”

MUHAMMAD ALI

5/5

“Good quality cables at competitive prices. Delivery was quick to Karachi. Will order again.”

IMRAN KHAN

Frequently asked

What is the price of 10mm 3 core flexible cable in Pakistan?
The price changes with the daily copper rate. We sell factory-direct from Lahore, below dealer rates. Message us on WhatsApp at +92 319 4262451 for today's price per meter.
What is 10mm 3 core flexible cable used for?
Three-phase machines and heavy portable equipment that needs an earth core: motor and machine leads, submersible pump motors, and trailing leads for portable machinery. Rated 57 A on method C with all three cores loaded as phases, and 63 A when the third core carries earth instead.
How many amps does 10mm 3 core flexible cable carry?
It depends on what you put in the third core. Wired as three phases with no neutral, all three conductors are loaded and the figure is 57 A — about 39 kVA at 400 V. Wired live, neutral and earth, only two are loaded and it rises to 63 A. Both are BS 7671 method C figures at 30°C ambient, before any correction for grouping, conduit or summer heat.
Can I use 10mm 3 core flexible cable for a submersible pump?
For the run from the starter down to the well head, yes — that is what the class 5 conductor and the earth core are for. The length that hangs permanently in water is a different job: it needs a cable rated for continuous submersion, usually the flat type the pump maker specifies. Confirm the submerged section with your pump installer before you order the whole drop.
Should I use standard cable instead of flexible?
Use flexible cable where the cable needs to move, coil, or trail — pumps, generators, portable tools. For a fixed run in conduit or clipped to a wall, standard cable is the normal choice.